Wi-Sun IoT NEMA Controller for Smart Streetlights - China Suppliers & Factory for Outdoor Lighting Solutions
Overview
Designed to seamlessly integrate with existing smart street lighting systems in the age of smart cities and advanced urban infrastructure, C-LUX launched the Smart Streetlight Controller with Wi-SUN Protocol, a cutting-edge innovation set to revolutionize the way we illuminate our streets and public spaces. With the Wi-SUN (Wireless Smart Utility Network) technology, this controller ensures robust and reliable communication, making it an ideal choice for smart street light projects in urban environments.
Functions and Characteristics
Enables individual remote program managements, ON / OFF / Dimming timers of streetlight lamps with 0-10V/PWM control gear.
Autonomous operation based on predefined schedules, light level sensor and adaptive lighting.
Adaptive lighting capabilities based on 0-10V/PWM digital input for motion sensing (optional).
Auto-commission with built-in GPS module.
Bandwidth efficient with minimal communication requirements.
Secure communication based on encryption keys.
Electrical parameters monitoring: (measured by 0-10V/PWM driver): V, W, A, Wh, PF and frequency.
Advanced data synchronization and notification mechanism.
Internal high precision Real time clock (RTC) with backup battery.
External infrared interface for local configuration.
Integrated light level sensor.
Over The Air (OTA) firmware update.
Alarm for repair automatically.
System Capabilities & Management
Automatic positioning system for the lighting devices to facilitate management, control, maintenance of lighting devices better.
Device status and real-time insightcontrol stay connected to your network.
Dimming for dynamic lighting maximise your benefits by associating sensors with grous of luminaires to trigger pre-defined lighting scenarios.
Firmware ota system for new function updating.
Individual or group control for light schedule program your lighting.
Maintenance system organise field operations through a fully intergrated maintenance system that will help you optimise your assetmanagement and maintenance.
Multi-tenant configure and manage different zonrs independently.
On-off for light schedule program your lighting.
Reports, alarms and data analytics anticipate and real time.
Timming for dynamic lighting schedule maximise your benefits by associating sensors with grous of luminaires to trigger pre-defined lighting scenarios.
Datasheet
Wi-Sun IoT NEMA Smart Controller of StreetlightFor C-Lux Gen2 Smart Street Light Management System |
|
| Lamp Type | LED, CF, HID with 0-10V/PWM control gear |
| Load Power | Depending on the lamp control gear |
| Additional Controlled Devices | Yes, independent controlled via 0-10V/PWM relay |
| Dimming Range | 1% - 100% |
| Control Interface | 0-10V/PWM (IEC 62386) |
| Power Supply | AC 100-270V |
| External Interface | Infrared |
| Network Interface | Wi-Sun |
| Frequencies | 865~880 MHz / Europe, 902~928 MHz / North America, 902~907 MHz / 915~928 MHz / Brazil, 915-928 MHz / Australia, 921.5~928 MHz - New Zealand. Approvals: ETSI EN 300 220-1, FCC 15.247, Industry Canada RSS-210, ANATEL, AS 4268 / ACMA, NZS 4268 / GURL |
| RF Communication Network | Data Rate: > 300kbps mesh networking, Automatic data routing with self-configuration, auto-healing & redundant uplinks. Spreading Technique: FHSS (Frequency Hopping), GFSK, Transmit Power: up to 1 W, Emission Designator: 250KF1D, Receiver Sensitivity: -98 dBm for 10% PER |
| Internet Protocol | IPv6, Protocol: IEEE 802.15.4g (WI-SUN Certified) |
| Inter-node Mesh Communication | Optionally available, with motion sensor or GIS add-on. Automatic and precise self-location and commissioning of the smart device. Standalone GPS, acquisition Sensitivity -130dBm |
| Average Power | 0.7W / 24V contact module 1 – NEMA (book 18) average poumption |
| Maximum Power | 1W / 24V contact module 1 – Zhaga (book 18) |
| Precision Real Time Clock | Battery operated |
| Real-time Lamp Operation | Yes |
| Digital Input | No |
| IP Level | IP66 |
| Size | 80 x 49 mm |
| Operating Temperature | -25°C to +65°C |
| Compliant Standards | Radio Equipment Directive (RED), 2014/53/EU / Restriction of the use of certain Hazardous Substances in electrical and electronic equipment Directive (RoHS), 2011/65/EU |